Herstellererklärung Manufacturer declaration Déclaration du fabricant Declaración del fabricante EHEDG and 3-A Installation and Cleaning ...

Die Seite wird erstellt Karl Merkel
 
WEITER LESEN
Herstellererklärung Manufacturer declaration Déclaration du fabricant Declaración del fabricante EHEDG and 3-A Installation and Cleaning ...
Herstellererklärung
Manufacturer declaration
Déclaration du fabricant
Declaración del fabricante

EHEDG and 3-A
Installation and Cleaning
Instructions
VEGAPOINT 11, 21, 31
Hygienische Prozessanschlüsse
Hygienic process fittings
Raccords process hygiéniques
Conexiones a proceso asépticas

Document ID: 62398
Herstellererklärung Manufacturer declaration Déclaration du fabricant Declaración del fabricante EHEDG and 3-A Installation and Cleaning ...
Inhaltsverzeichnis

Inhaltsverzeichnis
1   Zu diesem Dokument............................................................................................................... 3
    1.1 Funktion............................................................................................................................ 3
    1.2 Geltungsbereich................................................................................................................ 3
2   3-A-/EHEDG-Standards - Bedeutung und Umsetzung.......................................................... 4

3   Geräteausführungen................................................................................................................ 5

4   Montage..................................................................................................................................... 6

5   Instandhaltung, Reinigung, Bestimmungsgemäßer Gebrauch............................................ 9

6   Herstellererklärung................................................................................................................. 11
    6.1 3-A.................................................................................................................................. 11
    6.2 EHEDG........................................................................................................................... 12
7   3-A-Zertifikat............................................................................................................................ 13

8   EHEDG-Zertifikat..................................................................................................................... 18

                                                                                                                                                     62398-DE-230119

                                          Redaktionsstand: 2023-01-19

2                                            EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31
Herstellererklärung Manufacturer declaration Déclaration du fabricant Declaración del fabricante EHEDG and 3-A Installation and Cleaning ...
1 Zu diesem Dokument

                                                1     Zu diesem Dokument
                                                1.1    Funktion
                                                Die vorliegende Anleitung liefert Ihnen die wichtigsten Informationen
                                                für den Einsatz von Grenzschaltern.

                                                VEGAPOINT 11, 21
                                                nach "EHEDG Doc. 2, Doc. 8, Doc. 10 und 3-A Sanitary Standard for
                                                Sensors and Sensor Fittings and Connections, Number 74".

                                                VEGAPOINT 31
                                                nach "EHEDG Doc. 2, Doc. 8, Doc. 10 und 3-A Sanitary Standard for
                                                Level Sensing Devices for Dry Products, Number 50".

                                                1.2    Geltungsbereich
                                                Die Anleitung gilt für Grenzschalter VEGAPOINT 11, 21, 31 mit
                                                hygienischen Prozessanschlüssen und Dichtungen. Die Anschlüsse
                                                und Dichtungen sind in der Herstellererklärung in diesem Dokument
                                                aufgelistet.
62398-DE-230119

                  EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31                                 3
2 3-A-/EHEDG-Standards - Bedeutung und Umsetzung

                           2      3-A-/EHEDG-Standards - Bedeutung und
                                  Umsetzung
Bedeutung von 3-A          Die 3-A Sanitary Standards Incorporation (SSI) in den USA legt Stan-
                           dards für Werkstoffe, konstruktive Ausführung und Herstellmethoden
                           von Komponenten für hygienische Prozesse fest. Die Organisation
                           überwacht zudem die Einhaltung des hygienischen Designs dieser
                           Komponenten. Die Konformität wird durch eine unabhängige dritte
                           Instanz CCE (Certified Conformance Evaluator) geprüft. Bei Konfor-
                           mität vergibt die 3-A SSI eine Symbollizenz für das 3-A-Logo.

Bedeutung von EHEDG        Die European Hygienic Engineering & Design Group (EHEDG) ist ein
                           Konsortium aus Geräte- und Lebensmittelherstellern, Zulieferern der
                           Lebensmittelindustrie, Forschungsinstituten und Universitäten. Haupt-
                           ziel ist die Förderung sicherer Lebensmittel durch Verbesserung
                           von Hygienetechnik und -design in allen Bereichen der Lebensmit-
                           telherstellung. Hierzu hat die EHEDG Guidelines u. a. zur Hygie-
                           neauslegung von Maschinen und Anlagen sowie der Infrastruktur der
                           Lebensmittelproduktion erstellt.

Einsatz von Geräten nach Für den Einsatz im Lebensmittelbereich nach EHEDG bzw. 3-A gelten
EHEDG und 3-A            spezielle Anforderungen gegenüber Standardanwendungen. Dies gilt
                         insbesondere für:
                           •    Ausführung des Gehäuses (z. B. leichte Reinigbarkeit)
                           •    Aufbau des Prozessanschlusses (z. B. Sichtbarkeit möglicher
                                Leckagen)
                           •    Dichtungen (z. B. nach FDA- und EG1935/2004, bzw. beständig
                                gegenüber Prozess- und Reinigungsmedien)
                           •    Einbauposition am Behälter (z. B. Selbstdrainage)
                           •    Reinigung und Wartung (z. B. Intervalle, Methoden)
                           Die EHEDG- bzw. 3-A-Logos weisen nach, dass die Geräteausfüh-
                           rung geprüft und zertifiziert wurde. Das Zertifikat bezieht sich immer
                           auf eine Kombination von Sensor und Prozessanschluss.

                                                                                                       62398-DE-230119

4                              EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31
3 Geräteausführungen

                                                3     Geräteausführungen
                  Prozessanschlüsse             Für Einsätze nach den 3-A-/EHEDG-Standards sind ausschließlich
                                                die in Kapitel "Herstellererklärung" aufgeführten Prozessanschlüsse
                                                zu verwenden.
                                                Sie erfüllen die hygienischen Anforderungen aus den EHEDG Doc. 2,
                                                Doc. 8, Doc. 10 und den 3-A-Standard Nr. 74 und Nr. 50, einschließ-
                                                lich der Forderung nach Eigendrainage für den Fall eines Lecks in der
                                                Gerätedichtung.
62398-DE-230119

                  EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31                               5
4 Montage

                  4      Montage
                  Für eine Messstelle nach EHEDG- bzw. 3-A-Standard sind folgende
                  Punkte zu beachten:
                  •    Alle Bestandteile der Messstelle müssen 3-A-/EHEDG-konform
                       sein
                  •    Die Montageposition muss die Selbstdrainage des Sensors sowie
                       die Bohrung zur Leckageerkennung ermöglichen
                  •    Die Bohrung zur Leckageerkennung im Prozessanschluss muss
                       nach Montage sichtbar sein und möglichst senkrecht nach unten
                       weisen
                  •    Schweißverbindungen müssen eine Oberflächenrautiefe
                       Ra ≤ 0,8 µm aufweisen
                  •    Einschweißstutzen müssen frontbündig mit der Innenseite des
                       Behälters eingeschweißt werden. Für hygienegerechtes Schwei-
                       ßen ist die Schweißnorm AWS D18.3 zu beachten.

Montageposition   Vermeiden Sie in waagerechten Rohrleitungen die Montage im
                  oberen oder unteren Bereichs des Rohrs (siehe Ausschluss und
                  Begrenzung in der nachfolgenden Abbildung).
                  Im oberen Bereich des Rohrs können sich durch Lufteinschlüsse
                  Hohlräume bilden.
                  In waagerechten Rohrleitungen ist deshalb eine seitliche Montage
                  empfehlenswert.
                  Der Sensor ist für eine CIP-Reinigung optimiert und muss zur Reini-
                  gung nicht ausgebaut werden.
                  Wird der Sensor manuell gereinigt, dürfen keine Werkzeuge verwen-
                  det werden, die die PEEK-Oberfläche der Sensorspitze beschädigen.
                  Achten Sie bei der Wahl der Montage darauf, dass der Sensor selbst-
                  entleerend positioniert ist.
                                         x

                                                                       x

                          -90                                                  +90

                  Abb. 1: Montage in waagerechten Rohrleitungen
                  x    Empfohlener Montagebereich
                                                                                              62398-DE-230119

                  Achten Sie bei senkrechten Rohrleitungen darauf, den Sensor mög-
                  lichst bündig einzubauen.

6                     EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31
4 Montage

                                                Abb. 2: Montage in senkrechten Rohrleitungen

                  Hygieneadapter                Stellen Sie bei der Montage des Hygieneadapters sicher, dass die
                                                Bohrung zur Leckageerkennung im Prozessanschluss am tiefstmögli-
                                                chen Punkt liegt. Siehe folgende Abbildung:

                                                   1

                                                                                                      1

                                                       A                               B

                                                Abb. 3: Ausrichtung des Einschweißstutzen
                                                A Bohrung zur Leckageerkennung am Einschweißstutzen
                                                B Einbaurichtung nach unten
                                                1 Einbaurichtung seitlich - Leckagebohrung nach unten gerichtet

                  Montage des Sensors           Gehen Sie zur Sensormontage wie folgt vor:
                                                1. Vermeiden Sie bei der Montage des Sensors Verunreinigungen.
                                                    Nehmen Sie den Sensor deshalb erst kurz vor der Montage aus
                                                    seiner Verpackung und prüfen Sie insbesonders die Sensorspitze
                                                    auf Beschädigungen.
                                                2. Fetten Sie das Gewinde des Sensors dünn mit einem geeigneten
                                                   Fett ein (z. B. NSF H1 oder entsprechend FDA 21 CFR 178.3570).
                                                3. Schrauben Sie den Sensor vorsichtig von Hand ein.
                                                    Der VEGAPOINT 11, 21, 31 in Hygieneausführung dichtet elasto-
                                                    merfrei ohne spezielle Dichtung im Bereich der Sensorspitze.
                                                    Halten Sie deshalb das vorgeschriebene Drehmoment unbedingt
                                                    ein. Unterhalb des Sechskants bleibt dadurch ein kleiner Spalt (1)
                                                    [Abb. 4].
62398-DE-230119

                  EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31                                   7
4 Montage

                                    1

                                                                              2

                  A                         B

            Abb. 4: VEGAPOINT 11, 21, 31 in Hygieneausführung
            1    Unterhalb des Sechskants bleibt ein Spalt
            2    Detail der Dichtkante
            A    Hygieneausführung mit Einschweißadapter
            B    Hygieneausführung mit Clamp-Adapter

            Hinweis:
            Die Dichtwirkung des Sensors ist beim ersten Einschrauben optimal.
            Daher empfehlen wir, den Sensor nicht zu Testzwecken einzuschrau-
            ben.
            Prüfen Sie die Sensorspitze vor weiterem Einschrauben auf Be-
            schädigungen wie Kerben oder Rillen. Ersetzen Sie den Sensor im
            Zweifelsfall gegen einen neuen.
            4. Ziehen Sie den Sensor am Sechskant mit einem Drehmoment
               von 20 Nm (14.75 lbf ft) fest.
            5. Die Sensormontage ist damit abgeschlossen.
                                                                                        62398-DE-230119

8               EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31
5 Instandhaltung, Reinigung, Bestimmungsgemäßer Gebrauch

                                                5     Instandhaltung, Reinigung, Bestimmungs-
                                                      gemäßer Gebrauch
                  Instandhaltung                Es liegt in der Verantwortung des Anwenders, den hygienisch
                                                einwandfreien Zustand des Sensors über seine Nutzungsdauer
                                                sicherzustellen.
                                                Undichtigkeiten bei einer Dichtung stellen ein hygienisches Risiko
                                                dar. Um dies zu vermeiden sollen sie regelmäßig auf Beschädigun-
                                                gen geprüft werden. Sensor und Prozessadapter bilden eine Einheit
                                                und sollten bei einer Inspektion gemeinsam ausgebaut werden. Beim
                                                Sensor ist die zugängliche Oberfläche sorgfältig zu reinigen.
                                                Der Anwender richtet die Intervalle nach den Prozessbedingungen
                                                aus.
                                                Bei Varianten mit einer O-Ringdichtung empfehlen wir einen Aus-
                                                tausch nach 5000 Betriebsstunden, mindestens einmal im Jahr oder
                                                nach 500 Sterilisations- bzw. Reinigungszyklen. Beim O-Ringwechsel
                                                (relevant für Prozessanschluss AF) ist darauf zu achten keine metalli-
                                                schen Werkzeuge zu verwenden.

                  O-Ringwechsel                 Für einen ordnungsgemäßen Wechsel des O-Rings sollten folgende
                                                Dinge in angegebener Reihenfolge durchgeführt werden (relevant für
                                                VEGAPOINT mit Prozessanschluss AF):
                                                •   O-Ring von Hand aus der Dichtungsnut drücken bzw. schieben
                                                •   Reinigen der Dichtungsnut mit einem geeigneten Reinigungsuten-
                                                    sil, welches das Metall nicht beschädigt
                                                •   Prüfen, ob die gereinigte Dichtungsnut frei von Beschädigungen
                                                    ist
                                                •   Prüfen, ob der neue O-Ring die richtige Größe besitzt und frei von
                                                    Beschädigungen und Rissen ist
                                                •   Einfetten der Dichtungsnut und des O-Rings mit einem geeig-
                                                    neten Fett (z. B. Fette, welche nach NSF H1 oder entsprechend
                                                    FDA 21 CFR 178.3570 zugelassen sind)
                                                •   Aufschieben des O-Rings
                                                •   Sitz des O-Rings kontrollieren und prüfen, ob der O-Ring ohne
                                                    Verdrillung in der Dichtungsnut sitzt
                                                Für einen schnellen Wechsel der Dichtung empfehlen wir O-Ringe
                                                vorzuhalten. Der EPDM O-Ring 70.10-02 von Angst & Pfister bei dem
                                                Prozessanschluss AF besitzt die Maße 21,82 x 3,53 mm (VEGA-
                                                Artikelnummer 2.28170).

                  Reinigung                     Der Sensor ist für die CIP-Reinigung optimiert und muss für die Reini-
                                                gung nicht ausgebaut werden.
                                                Beim Einbau in den Tank ist darauf zu achten, dass die Reinigungs-
                                                armatur so positioniert wird, dass der Anschluss als auch der Sensor
                                                vollständig benetzt und gereinigt werden kann.
62398-DE-230119

                                                Falls eine ausbaufreie Validierung nicht möglich ist, empfiehlt sich zur
                                                Sicherstellung des Reinigungserfolges ein Ausbau.
                                                Es liegt in der Verantwortung des Anwenders, die Beständigkeit des
                                                Dichtungswerkstoffes sowie des Sensors gegenüber dem Produkt

                  EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31                               9
5 Instandhaltung, Reinigung, Bestimmungsgemäßer Gebrauch

                            und dem Reinigungsprozess sicherzustellen. Grundlage sind Bestän-
                            digkeitslisten sowie die technischen Daten des jeweiligen Sensors.
                            Sollte der Bereich hinter der Dichtung verschmutzt werden, ist dieser
                            Bereich mit einen geeigneten Reiniger einzuweichen und anschlie-
                            ßend mit einem geeinigten Reinigungsutensil, welches den Edelstahl
                            nicht beschädigt, zu reinigen.

Bestimmungsgemäßer          Salzige und saure Lebensmittel wie z. B. Würzkonzentrate, sowie
Gebrauch                    stark oxidierende oder chlorhaltige Reinigungsmittel, insbesondere
                            bei hohen Temperaturen und längerer Einwirkzeit können auch bei
                            Edelstahl zu Korrosion führen.
                            Die medienberührende Sensorspitze ist aus PEEK Victrex 450G. Das
                            Material ist geeignet auch für häufige Dampfsterilisation und hydro-
                            lysebeständig gegen Wasser, Wasserdampf und Salzwasser. Details
                            zur Beständigkeit finden Sie auf der Internetseite der Firma Victrex.
                            Zur Aufrechterhaltung der hygienischen Integrität ist eine regelmäßi-
                            ge visuelle Inspektion der medienberührenden Teile und gegebenen-
                            falls ein Austausch zu empfehlen.

                                                                                                      62398-DE-230119

10                            EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31
6 Herstellererklärung

                                                6     Herstellererklärung
                                                6.1    3-A

                                                Standard 74
                                                Wir erklären hiermit, dass die Geräte- und Prozessanschlusskom-
                                                binationen folgender Ausführungen des VEGAPOINT 11, 21 den
                                                Anforderungen des 3-A-Standards 74 entsprechen.

                                                VEGAPOINT 11, 21 mit Hygieneadapter P
                                                In der Ausführung: P11(**).[A oder D][AC]*
                                                In der Ausführung: P21(**).****[A oder D][AC]***
                                                •   In Verbindung mit den Hygieneadaptern
                                                    –– HYGADAPT-P.D[AT, AR, U5, E2, E3, BA, AD, AC, KA, Q6, KW,
                                                       FR, FS oder 7F]

                                                VEGAPOINT 11, 21 mit Hygieneadapter L
                                                In der Ausführung: P11(**).[A oder D][AF]*
                                                In der Ausführung: P21(**).****[A oder D][AF]***
                                                •   In Verbindung mit den Hygieneadaptern
                                                    –– HYGADAPT-L.D[AT, AR, E2, E3, BA, AD, AC, Q6, KW, FR, FS
                                                       oder 7F]

                                                VEGAPOINT 21
                                                In der Ausführung: P21(**).****[A oder D][AN, AP oder AQ]***

                                                Standard 50
                                                Wir erklären hiermit, dass die Geräte- und Prozessanschlusskombi-
                                                nationen folgender Ausführungen des VEGAPOINT 31 den Anforde-
                                                rungen des 3-A-Standards 50 entsprechen.
                                                Die dazugehörige Zertifikatsnummer für den Standort VEGA Griesha-
                                                ber KG, Schiltach, Deutschland lautet 3808.

                                                VEGAPOINT 31 mit Hygieneadapter P
                                                In der Ausführung: P31(**).****[A oder D][AC]*
                                                •   In Verbindung mit den Hygieneadaptern
                                                    –– HYGADAPT-P.D[AT, AR, U5, E2, E3, BA, AD, AC, KA, Q6, KW,
                                                       FR, FS oder 7F]

                                                VEGAPOINT 31 mit Hygieneadapter L
                                                In der Ausführung: P31(**).****[A oder D][AF]*
                                                •   In Verbindung mit den Hygieneadaptern
                                                    –– HYGADAPT-L.D[AT, AR, E2, E3, BA, AD, AC, Q6, KW, FR, FS
                                                       oder 7F]
62398-DE-230119

                                                VEGAPOINT 31
                                                In der Ausführung: P31(**).****[A oder D][AN, AP oder AQ]***

                  EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31                              11
6 Herstellererklärung

                        6.2      EHEDG
                        Wir erklären hiermit, dass die Geräte- und Prozessanschlusskombi-
                        nationen folgender Ausführungen des VEGAPOINT 11, 21, 31 den
                        Anforderungen EHEDG Doc. 2, Doc. 8, Doc. 10 entsprechen.

                        VEGAPOINT 11, 21, 31 mit Hygieneadapter P
                        In der Ausführung: P11(**).D[AC]*
                        In der Ausführung: P21(**).****D[AC]***
                        In der Ausführung: P31(**).****D[AC]***
                        •    In Verbindung mit den Hygieneadaptern
                             –– HYGADAPT-P.D[U5, E2, E3, BA, AD, AC, KA, Q6, KW, FR, FS
                                oder 7F]
                             –– HYGADAPT-P.D[AT oder AR] nur in Kombination mit Clamp
                                seals Combifit International B.V., The Netherlands

                        VEGAPOINT 21, 31
                        In der Ausführung: P21(**).****D[AN, AP oder AQ]*** in Kombination
                        mit Clamp seals Combifit International B.V., The Netherlands
                        In der Ausführung: P31(**).****D[AN, AP oder AQ]*** in Kombination
                        mit Clamp seals Combifit International B.V., The Netherlands

                                                                                                    62398-DE-230119

12                          EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31
7 3-A-Zertifikat

                                                7     3-A-Zertifikat
62398-DE-230119

                  EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31                13
7 3-A-Zertifikat

                                                                                           62398-DE-230119

14                 EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31
7 3-A-Zertifikat
62398-DE-230119

                  EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31                15
7 3-A-Zertifikat

                                                                                           62398-DE-230119

16                 EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31
7 3-A-Zertifikat
62398-DE-230119

                  EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31                17
8 EHEDG-Zertifikat

                     8      EHEDG-Zertifikat

                                                                                                 62398-DE-230119

18                       EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31
8 EHEDG-Zertifikat
62398-DE-230119

                  EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31                  19
8 EHEDG-Zertifikat

                                                                                             62398-DE-230119

20                   EHEDG und 3-A, Einbau- und Reinigungsanleitung • VEGAPOINT 11, 21, 31
Contents

Contents
1   About this document................................................................................................................ 3
    1.1 Function............................................................................................................................ 3
    1.2 Scope................................................................................................................................ 3
2   3-A-/EHEDG-Standards - Meaning and implementation....................................................... 4

3   Instrument versions.................................................................................................................. 5

4   Mounting.................................................................................................................................... 6

5   Maintenance, cleaning, proper use......................................................................................... 9

6   Manufacturer declaration....................................................................................................... 11
    6.1 3-A.................................................................................................................................. 11
    6.2 EHEDG........................................................................................................................... 12
7   3-A certificate.......................................................................................................................... 13

8   EHEDG certificate................................................................................................................... 18

                                                                                                                                                     62398-EN-230119

                                          Editing status: 2023-01-19

2                                       EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31
1 About this document

                                                 1      About this document
                                                 1.1     Function
                                                 This instructions manual provides the most important information
                                                 needed for using of level switches.

                                                 VEGAPOINT 11, 21
                                                 according to " EHEDG Doc. 2, Doc. 8, Doc. 10 and 3-A Sanitary
                                                 Standard for Sensors and Sensor Fittings and Connections, Number
                                                 74".

                                                 VEGAPOINT 31
                                                 according to " EHEDG Doc. 2, Doc. 8, Doc. 10 and 3-A Sanitary
                                                 Standard for Level Sensing Devices for Dry Products, Number 50".

                                                 1.2     Scope
                                                 These instructions apply to limit switches VEGAPOINT 11, 21, 31 with
                                                 hygienic process fittings and seals. You can find the fittings and seals
                                                 in the manufacturer declaration of this document.
62398-EN-230119

                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31                         3
2 3-A-/EHEDG-Standards - Meaning and implementation

                            2     3-A-/EHEDG-Standards - Meaning and
                                  implementation
Meaning of 3-A              3-A Sanitary Standards Incorporation (SSI) in the USA sets standards
                            for materials, design and manufacturing methods for components
                            used in hygienic processes. The organization also monitors compli-
                            ance with the hygienic design of these components. Conformity is
                            verified by an independent third party CCE (Certified Conformance
                            Evaluator). In the case of conformity, 3-A SSI issues a symbol license
                            for the 3-A logo.

Meaning of EHEDG            The European Hygienic Engineering & Design Group (EHEDG) is
                            a consortium of equipment and food manufacturers, food industry
                            suppliers, research institutes and universities. The main objective is
                            to promote safe food by improving hygiene technology and design in
                            all areas of food production. To this end, the EHEDG has drawn up
                            guidelines for the hygienic design of machines and plants as well as
                            the infrastructure of food production.

Use of instruments ac-      For use in the food sector according to EHEDG or 3-A, special
cording to EHEDG and        requirements apply compared to standard applications. This applies
3-A                         in particular to:
                            •   Version of the housing (e.g. easy cleaning)
                            •   Configuration of the process fitting (e.g. visibility of possible leak-
                                age)
                            •   Seals (e.g. according to FDA and EG1935/2004, or resistant to
                                process and cleaning media)
                            •   Installation position on the vessel (e.g. self-drainage)
                            •   Cleaning and maintenance (e.g. intervals, methods)
                            The EHEDG and 3-A logos prove that the device version has been
                            tested and certified. The certificate always refers to a combination of
                            sensor and process fitting.

                                                                                                          62398-EN-230119

4                          EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31
3 Instrument versions

                                                 3      Instrument versions
                  Process fittings               Only process fittings listed in chapter " Manufacturer declaration" may
                                                 be used for installations according to 3-A/EHEDG standards.
                                                 They meet the hygienic requirements of EHEDG Doc. 2, Doc. 8, Doc.
                                                 10 and the 3-A Standard No. 74 and No. 50, including the requirement
                                                 for self-drainage in the event of a leak in the device seal.
62398-EN-230119

                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31                        5
4 Mounting

                         4      Mounting
                         Note the following items for a measuring point according to EHEDG
                         or 3-A standard:
                         •   All parts of the measuring point must comply with 3-A/EHEDG
                         •   The mounting position must allow the self-drainage of the sensor
                             as well as the hole for leakage detection
                         •   The hole for leakage detection in the process fitting must be visible
                             after mounting and possibly point vertically downward
                         •   Welded connections must have a surface roughness Ra ≤ 0.8 µm
                         •   Welding sockets must be welded flush with the inside of the
                             vessel. The welding standard AWS D18.3 must be observed for
                             hygienic welding.

Installation position    In horizontal pipelines, avoid mounting in the upper or lower area of
                         the pipe (see exclusion and limitation in the figure below).
                         In the upper part of the pipe cavities can form due to air inclusions.
                         In horizontal pipelines, lateral installation is therefore recommended.
                         The sensor is optimized for CIP cleaning and does not have to be
                         removed for cleaning.
                         If the sensor is cleaned manually, do not use tools that damage the
                         PEEK surface of the sensor tip.
                         When selecting the mounting, make sure that the sensor is positioned
                         so that it empties itself.
                                                   x

                                                                               x

                                 -90                                                   +90

                         Fig. 1: Installation in horizontal pipelines
                         x   Recommended mounting area

                         For vertical pipelines, make sure that the sensor is installed as flush
                         as possible.
                                                                                                       62398-EN-230119

6                       EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31
4 Mounting

                                                 Fig. 2: Installation in vertical pipelines

                  Hygienic adapter               When installing the hygienic adapter, make sure that the hole for leak-
                                                 age detection in the process fitting is at the lowest possible point. See
                                                 the figure below:

                                                     1

                                                                                                       1

                                                         A                                    B

                                                 Fig. 3: Orientation of the welded socket
                                                 A Hole for leakage detection on the welding socket
                                                 B Mounting direction downwards
                                                 1 Mounting direction lateral - Leakage hole directed downwards

                  Mounting the sensor            For sensor mounting proceed as follows:
                                                 1. Avoid contamination when mounting the sensor.
                                                      Therefore, only remove the sensor from its packaging shortly be-
                                                      fore mounting and, in particular, check the sensor tip for damage.
                                                 2. Grease the thread of the sensor thinly with a suitable grease (e.g.
                                                    NSF H1 or according to FDA 21 CFR 178.3570).
                                                 3. Screw in the sensor carefully by hand.
                                                      The VEGAPOINT 11, 21, 31 in hygienic version seals elastomer-
                                                      free without special seal in the area of the sensor tip.
                                                      It is therefore essential that you observe the prescribed torque.
                                                      This leaves a small gap (1) below the hexagon [Fig. 4].
62398-EN-230119

                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31                            7
4 Mounting

                                      1

                                                                                  2

                   A                          B

              Fig. 4: VEGAPOINT 11, 21, 31 in hygienic version
              1   Below the hexagon remains a gap
              2   Detail of the sealing edge
              A   Hygienic version with welding adapter
              B   Hygienic version with clamp adapter

              Note:
              The sealing effect of the sensor is optimal when first screwed in. We
              therefore recommend not screwing in the sensor for test purposes.
              Before further screwing in, check the sensor tip for damage such as
              notches or grooves. If in doubt, replace the sensor with a new one.
              4. Tighten the sensor on the hexagon with a torque of 20 Nm
                 (14.75 lbf ft).
              5. The sensor is mounted.                                                     62398-EN-230119

8            EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31
5 Maintenance, cleaning, proper use

                                                 5      Maintenance, cleaning, proper use
                  Maintenance                    It is the responsibility of the user to ensure the hygienically safe condi-
                                                 tion of the sensor during its entire service life.
                                                 Leaks in a gasket represent a hygienic risk. To avoid this, they should
                                                 be checked regularly for damage. Sensor and process adapter form
                                                 a unit and should be removed together during an inspection. The ac-
                                                 cessible surface of the sensor must be carefully cleaned.
                                                 The user plans the intervals according to the process conditions.
                                                 For variants with an O-ring seal, we recommend replacement after
                                                 5000 operating hours, at least once a year or after 500 sterilisation
                                                 or cleaning cycles. When replacing the O-ring (relevant for process
                                                 fitting AF), do not use any metallic tools.

                  O-ring change                  For proper replacement of the O-ring, the following should be carried
                                                 out in the sequence indicated (relevant for VEGAPOINT with process
                                                 fitting AF):
                                                 •   Push the O-ring out of the seal groove manually
                                                 •   Clean the seal groove with a suitable cleaning utensil that does
                                                     not damage the metal
                                                 •   Check that the cleaned seal groove is free of damage
                                                 •   Check that the new O-ring is of the correct size and free from dam-
                                                     age and cracks
                                                 •   Grease the seal groove and the O-ring with a suitable grease (e.g.
                                                     greases approved according to NSF H1 or FDA 21 CFR 178.3570)
                                                 •   Sliding on the O-ring
                                                 •   Check the position of the O-ring and make sure that the O-ring is
                                                     fitted in the seal groove without twisting
                                                 We recommend using O-rings for a quick change of the seal. The
                                                 EPDM O-ring 70.10-02 from Angst & Pfister for process fitting AF
                                                 measures 21.82 x 3.53 mm (VEGA article number 2.28170).

                  Cleaning                       The sensor is optimized for CIP cleaning and does not have to be
                                                 removed for the cleaning.
                                                 When installing in the tank, make sure that the cleaning fitting is posi-
                                                 tioned so that the connection as well as the sensor can be completely
                                                 wetted and cleaned.
                                                 If a validation without removal is not possible, it is recommended to
                                                 remove the unit to ensure successful cleaning.
                                                 It is the responsibility of the user to ensure the resistance of the
                                                 sealing material and the sensor against the product and the cleaning
                                                 process. This is based on resistance lists and the technical data of the
                                                 respective sensor.
                                                 If the area behind the seal becomes dirty, soak this area with a suit-
                                                 able cleaner and then clean it with a suitable cleaning utensil that
62398-EN-230119

                                                 does not damage the stainless steel.

                  Intended use                   Salty and acidic foodstuffs such as seasoning concentrates, as well
                                                 as strongly oxidizing or chlorine-containing cleaning agents, espe-

                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31                            9
5 Maintenance, cleaning, proper use

                              cially at high temperatures and longer exposure times, can also lead
                              to corrosion of stainless steel.
                              The sensor tip in contact with the medium is made of PEEK Victrex
                              450G. The material is also suitable for frequent steam sterilization
                              and hydrolysis resistant to water, steam and salt water. Details on the
                              resistance can be found on the Victrex website.
                              In order to maintain hygienic integrity, regular visual inspection of the
                              parts in contact with the medium and, if necessary, replacement are
                              recommended.

                                                                                                            62398-EN-230119

10                           EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31
6 Manufacturer declaration

                                                 6      Manufacturer declaration
                                                 6.1     3-A

                                                 Standard 74
                                                 We hereby declare that the instrument and process fitting combi-
                                                 nations of the following versions of VEGAPOINT 11, 21 meet the
                                                 requirements of 3-A standard 74.

                                                 VEGAPOINT 11, 21 with hygienic adapter P
                                                 In version: P11(**).[A or D][AC]*
                                                 In version: P21(**).****[A or D][AC]***
                                                 •   In conjunction with the hygienic adapters
                                                     –– HYGADAPT-P.D[AT, AR, U5, E2, E3, BA, AD, AC, KA, Q6, KW,
                                                        FR, FS or 7F]

                                                 VEGAPOINT 11, 21 with hygienic adapter L
                                                 In version: P11(**).[A or D][AF]*
                                                 In version: P21(**).****[A or D][AF]***
                                                 •   In conjunction with the hygienic adapters
                                                     –– HYGADAPT-L.D[AT, AR, E2, E3, BA, AD, AC, Q6, KW, FR, FS
                                                        or 7F]

                                                 VEGAPOINT 21
                                                 In version: P21(**).****[A or D][AN, AP or AQ]***

                                                 Standard 50
                                                 We hereby declare that the instrument and process fitting combina-
                                                 tions of the following versions of VEGAPOINT 31 meet the require-
                                                 ments of 3-A standard 50.
                                                 The associated certificate number for the VEGA Grieshaber KG,
                                                 Schiltach, Germany site is 3808.

                                                 VEGAPOINT 31 with hygienic adapter P
                                                 In version: P31(**).****[A or D][AC]*
                                                 •   In conjunction with the hygienic adapters
                                                     –– HYGADAPT-P.D[AT, AR, U5, E2, E3, BA, AD, AC, KA, Q6, KW,
                                                        FR, FS or 7F]

                                                 VEGAPOINT 31 with hygienic adapter L
                                                 In version: P31(**).****[A or D][AF]*
                                                 •   In conjunction with the hygienic adapters
                                                     –– HYGADAPT-L.D[AT, AR, E2, E3, BA, AD, AC, Q6, KW, FR, FS
                                                        or 7F]
62398-EN-230119

                                                 VEGAPOINT 31
                                                 In version: P31(**).****[A or D][AN, AP or AQ]***

                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31                          11
6 Manufacturer declaration

                              6.2     EHEDG
                              We hereby declare that the instrument and process fitting combina-
                              tions of the following versions of VEGAPOINT 11, 21, 31 meet the
                              requirements of EHEDG Doc. 2, Doc. 8, Doc. 10.

                              VEGAPOINT 11, 21, 31 with hygienic adapter P
                              In version: P11(**).D[AC]*
                              In version: P21(**).****D[AC]***
                              In version: P31(**).****D[AC]***
                              •   In conjunction with the hygienic adapters
                                  –– HYGADAPT-P.D[U5, E2, E3, BA, AD, AC, KA, Q6, KW, FR, FS
                                     or 7F]
                                  –– HYGADAPT-P.D[AT or AR] only in combination with Clamp
                                     seals Combifit International B.V., The Netherlands

                              VEGAPOINT 21, 31
                              In the version: P21(**).****D[AN, AP or AQ]*** in combination with
                              Clamp seals Combifit International B.V., The Netherlands
                              In the version: P31(**).****D[AN, AP or AQ]*** in combination with
                              Clamp seals Combifit International B.V., The Netherlands

                                                                                                            62398-EN-230119

12                           EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31
7 3-A certificate

                                                 7      3-A certificate
62398-EN-230119

                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31                 13
7 3-A certificate

                                                                                                   62398-EN-230119

14                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31
7 3-A certificate
62398-EN-230119

                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31                 15
7 3-A certificate

                                                                                                   62398-EN-230119

16                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31
7 3-A certificate
62398-EN-230119

                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31                 17
8 EHEDG certificate

                       8     EHEDG certificate

                                                                                                     62398-EN-230119

18                    EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31
8 EHEDG certificate
62398-EN-230119

                  EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31                   19
8 EHEDG certificate

                                                                                                     62398-EN-230119

20                    EHEDG and 3-A, Installation and Cleaning Instructions • VEGAPOINT 11, 21, 31
Table des matières

Table des matières
1   À propos de ce document........................................................................................................ 3
    1.1 Fonction............................................................................................................................ 3
    1.2 Domaine de validité........................................................................................................... 3
2   Standards 3-A/EHEDG - signification et implémentation..................................................... 4

3   Versions d'appareil................................................................................................................... 5

4   Montage..................................................................................................................................... 6

5   Maintenance, nettoyage, utilisation conforme à la destination........................................... 9

6   Déclaration du fabricant......................................................................................................... 11
    6.1 3-A.................................................................................................................................. 11
    6.2 EHEDG........................................................................................................................... 12
7   Certificat 3-A............................................................................................................................ 13

8   Certificat EHEDG..................................................................................................................... 18

                                                                                                                                                     62398-FR-230119

                                          Date de rédaction : 2023-01-19

2                                      EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31
1 À propos de ce document

                                                 1     À propos de ce document
                                                 1.1     Fonction
                                                 Les présentes instructions fournissent les informations les plus impor-
                                                 tantes pour l'utilisation des détecteurs de niveau.

                                                 VEGAPOINT 11, 21
                                                 selon " EHEDG doc. 2, doc. 8, doc. 10 et 3-A Sanitary Standard for
                                                 Sensors and Capteur Fittings and Connections, Number 74".

                                                 VEGAPOINT 31
                                                 selon " EHEDG Doc. 2, Doc. 8, Doc. 10 et 3-A Sanitary Standard for
                                                 Level Sensing Devices for Dry Products, Number 50".

                                                 1.2     Domaine de validité
                                                 La notice est valable pour les détecteurs VEGAPOINT 11, 21, 31
                                                 avec raccords hygiéniques et joints. Les raccords et les joints sont ré-
                                                 pértoriés dans la déclaration du fabricant contenu dans ce document.
62398-FR-230119

                  EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31                          3
2 Standards 3-A/EHEDG - signification et implémentation

                              2     Standards 3-A/EHEDG - signification et
                                    implémentation
Signification de 3-A          La 3-A Sanitary Standards Incorporation (SSI) aux États-Unis définit
                              des normes pour les matériaux, l'exécution de construction et les
                              méthodes de fabrication des composants pour les process hygié-
                              niques. L'organisation surveille en outre le respect de la conception
                              hygiénique de ces composants. La conformité est contrôlée par une
                              instance CCE (Certified Conformance Evaluator) tiers indépendante.
                              Si la conformité est données, la 3-A SSI octroie une licence de sym-
                              bole pour le logo 3-A.

Signification d'EHEDG         Le European Hygienic Engineering & Design Group (EHEDG) est un
                              consortium de fabricants d'appareils et de denrées alimentaires, de
                              fournisseurs de l'industrie agroalimentaire, d'instituts de recherche
                              et d'universités. L'objectif principal est la promotion de denrées ali-
                              mentaires sûres par l'amélioration de la technique et de la conception
                              de l'hygiène dans tous les domaines de la fabrication de produits
                              alimentaires. L'EHEDG a rédigé des lignes directrices entre autres
                              pour la conception hygiénique des machines et installations ainsi que
                              de l'infrastructure de la production agroalimentaire.

Mise en œuvre d'appa-         Des exigences spéciales s'appliquent pour la mise en œuvre dans
reils selon EHEDG et 3-A      le domaine des denrées alimentaires selon EHEDG ou 3-A. Cela
                              concerne en particulier :
                              •   La version du boîtier (par ex. bonne nettoyabilité)
                              •   La structure du raccord process (par ex. visibilité des fuites poten-
                                  tielles)
                              •   Joints (par ex. selon FDA et EG1935/2004, ou résistants aux
                                  produits de nettoyage et du process)
                              •   La position de montage au niveau du réservoir (par ex. autodrai-
                                  nage)
                              •   Le nettoyage et la maintenance (par ex. périodicités, méthodes)
                              Les logos EHEDG ou 3-A prouvent que la version de l'appareil a été
                              contrôlée et certifiée. Le certificat se fonde toujours sur une combinai-
                              son de capteur et de raccord process.
                                                                                                           62398-FR-230119

4                           EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31
3 Versions d'appareil

                                                 3     Versions d'appareil
                  Raccords process               Pour les utilisations selon les normes 3-A/EHEDG, les raccords pro-
                                                 cess indiqués dans le chapitre " Déclaration du fabricant" doivent être
                                                 utilisés de manière standard.
                                                 Ils satisfont les exigences en matière d'hygiène d'EHEDG, doc. 2,
                                                 doc. 8 et doc.10 ainsi que de la norme 3-A- N° 74 et N° 50, y compris
                                                 l'impératif de drainage propre en cas de fuite dans le joint de l'appa-
                                                 reil.
62398-FR-230119

                  EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31                         5
4 Montage

                        4     Montage
                        Pour une voie de mesure selon la norme 3-A ou EHEDG, les points
                        suivants doivent être respectés :
                        •   Tous les composants de la voie de mesure doivent être conformes
                            à 3-A/EHEDG
                        •   La position de montage doit permettre l'autodrainage du capteur
                            ainsi que le perçage pour la reconnaissance de fuites
                        •   Après le montage, le perçage pour la reconnaissance de fuites
                            doit être visible et orienté verticalement vers le bas
                        •   Les raccords soudés doivent avoir une profondeur de rugosité de
                            surface Ra ≤ 0,8 µm
                        •   Les raccords à souder doivent être soudés arasants sur le côté
                            intérieur de la cuve. Respecter obligatoirement la norme de sou-
                            dage AWS D18.3 pour souder dans le respect de l'hygiène.

Position de montage     Évitez le montage dans les conduites tubulaires horizontales dans
                        la zone supérieure ou inférieure du tube (voir Exclusion et limitation
                        dans l'illustration suivante).
                        Un espace vide peut se former dans la zone supérieure du tube du
                        fait des inclusions d'air.
                        C'est pourquoi il est recommandé de procéder à un montage latéral
                        dans les conduites tubulaires horizontales.
                        Le capteur est optimisé pour un nettoyage CIP et ne doit pas être
                        déposé pour le nettoyage.
                        Si le capteur est nettoyé manuellement, il est interdit d'utiliser des
                        outils qui endommagent la surface PEEK de la pointe du capteur.
                        Lors du montage, veillez que le capteur soit positionné de manière à
                        se vider de lui-même.
                                                x

                                                                                 x

                               -90                                                   +90

                        Fig. 1: Montage dans les conduites tubulaires horizontales
                        x   Zone de montage recommandée

                        Dans le cas de conduites tubulaires verticales, assurez-vous de
                                                                                                     62398-FR-230119

                        monter le capteur aussi arasant que possible.

6                     EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31
4 Montage

                                                 Fig. 2: Montage dans les conduites tubulaires verticales

                  Adaptateur hygiénique          Lors du montage de l'adaptateur hygiénique, assurez-vous que l'alé-
                                                 sage pour la détection de fuite se trouve au point le plus bas possible
                                                 du raccord process. Reportez-vous à l'illustration suivante :

                                                     1

                                                                                                            1

                                                         A                                 B

                                                 Fig. 3: Alignement du raccord à souder
                                                 A Perçage pour la reconnaissance de fuites sur le raccord à souder
                                                 B Sens de montage vers le bas
                                                 1 Sens de montage latéral - alésages de fuite orienté vers le bas

                  Montage du capteur             Pour le montage du capteur, procédez de manière suivante :
                                                 1. Évitez les impuretés lors du montage du capteur.
                                                     C'est pourquoi, sortez le capteur de son emballage seulement
                                                     juste avant le montage et contrôlez en particulier si la pointe du
                                                     capteur présente des dommages.
                                                 2. Graissez le filetage du capteur finement avec une graisse adap-
                                                    tée (par ex. NSF H1 ou conforme à FDA 21 CFR 178.3570).
                                                 3. Vissez le capteur avec précaution à la main.
                                                     Le VEGAPOINT 11, 21, 31 en version hygiénique étanchéifie
                                                     sans élastomère et sans joint spécial dans la zone de la pointe du
                                                     capteur.
                                                     C'est pourquoi il est absolument impératif de respecter le couple
                                                     prescrit. Il reste ainsi une légère fente (1) en dessous de l'hexa-
62398-FR-230119

                                                     gone [fig. 4].

                  EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31                            7
4 Montage

                                     1

                                                                                 2

                   A                         B

              Fig. 4: VEGAPOINT 11, 21, 31 en version hygiénique
              1   Il reste une fente en dessous de l'hexagone
              2   Détail du bord d'étanchéité
              A   Version hygiénique avec adaptateur à souder
              B   Version hygiénique avec adaptateur Clamp

              Remarque:
              L'éfficacité d'étanchétié du capteur est optimale lors du premier
              vissage. C'est pourquoi nous recommandons de ne pas visser le
              capteur à des fins de test.
              Contrôlez la pointe du capteur avant de le visser pour détecter tout
              dommage, tel qu'une entaille ou des rainures. En cas de doute, rem-
              placez le capteur par un neuf.
              4. Serrez le capteur sur l'hexagone à un couple de 20 Nm
                 (14.75 lbf ft).
              5. Vous avez terminé le montage du capteur.
                                                                                           62398-FR-230119

8           EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31
5 Maintenance, nettoyage, utilisation conforme à la destination

                                                 5     Maintenance, nettoyage, utilisation
                                                       conforme à la destination
                  Entretien                      L'utilisateur est responsable d'assurer l'état hygiénique irréprochable
                                                 du capteur pendant toute sa durée d'utilisation.
                                                 Les fuites au niveau d'un joint constituent un risque hygiénique. Pour
                                                 l'éviter, il est nécessaire de les soumettre régulièrement à un contrôle
                                                 d'endommagement. Le capteur et l'adaptateur process constituent
                                                 une unité et doivent être démontés ensemble pour une inspection.
                                                 Nettoyer soigneusement la surface accessible sur le capteur.
                                                 L'utilisateur adapte les périodicités selon les conditions process.
                                                 Sur les versions avec un joint torique, nous recommandons un rem-
                                                 placement après 5000 heures de service, au moins une fois par an ou
                                                 après 500 cycles de stérilisation ou nettoyage. Lors du remplacement
                                                 du joint torique (significatif pour le raccord process AF), il convient de
                                                 veiller à ne pas utiliser d'outils métalliques.

                  Remplacement du joint          Pour un remplacement correct du joint torique, les opérations sui-
                  torique                        vantes doivent être effectuées dans l'ordre indiqué (pertinent pour
                                                 VEGAPOINT avec raccord process AF) :
                                                 •   Appuyer sur ou pousser le joint torique hors de la rainure d'étan-
                                                     chéité à la main
                                                 •   Nettoyer la rainure d'étanchéité avec un outil de nettoyage appro-
                                                     prié qui n'endommage pas le métal
                                                 •   Contrôler si la rainure d'étanchéité nettoyée est exempte de
                                                     dommages
                                                 •   Contrôler si le nouveau joint torique présente les bonnes dimen-
                                                     sions et s'il est exempt de dommages et de fissures
                                                 •   Graisser la rainure d'étanchéité et le joint torique avec une graisse
                                                     appropriée (par ex. des graisses autorisées selon NSF H1 ou
                                                     selon FDA 21 CFR 178.3570)
                                                 •   Insertion du joint torique
                                                 •   Contrôler le logement du joint torique et vérifier si le joint torique
                                                     est logé dans la rainure d'étanchéité sans torsion
                                                 Nous recommandons de conserver en stock des joints toriques afin
                                                 de pouvoir procéder au remplacement rapide du joint. Les dimen-
                                                 sions du joint torique en EPDM 70.10-02 d'Angst & Pfister sur le
                                                 raccord process AF sont 21,82 x 3,53 mm (référence VEGA 2.28170).

                  Nettoyage                      Le capteur est optimisé pour le nettoyage CIP et ne doit pas être
                                                 déposé pour le nettoyage.
                                                 Lors du montage dans la cuve, il convient de veiller à positionner la
                                                 ferrure de nettoyage de telle manière qu'aussi bien le raccordement
                                                 que le capteur puissent être totalement enduits et nettoyés.
                                                 Au cas où une validation sans dépose n'est pas possible, il est
62398-FR-230119

                                                 recommandé de procéder à la dépose pour assurer le succès du
                                                 nettoyage.
                                                 Il est du ressort de la responsabilité de l'utilisateur d'assurer la résis-
                                                 tance du matériau du joint ainsi que du capteur vis-à-vis du produit et

                  EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31                             9
5 Maintenance, nettoyage, utilisation conforme à la destination

                                du process de nettoyage. Des listes de résistance ainsi que les carac-
                                téristiques techniques du capteur respectif en constituent la base.
                                Si la zone derrière le joint devait être encrassée, la tremper avec un
                                détergent approprié et ensuite la nettoyer avec un ustensile de net-
                                toyage adapté qui n'endommage pas l'acier inoxydable.

Utilisation conforme            Les denrées alimentaires salées et acides, comme par ex. les
                                concentrés d'épices ainsi que les détergents fortemetn oxydant
                                ou contenant du chlore peuvent provoquer la corrosion de l'acier
                                inoxydable, en particulier à hautes températures et en cas de durée
                                d'action prolongée.
                                La pointe du capteur en contact avec le produit est en PEEK Victrex
                                450G. Cette matière est appropriée aussi pour une stérilisation
                                fréquente à la vapeur et résistant à l'hydrolyse contre l'eau, la vapeur
                                d'eau et l'eau salée. Vous trouverez les détails relatifs à la résistance
                                sur la page Internet de la société Victrex.
                                Il est recommandé de procéder à un contrôle visuel régulier des
                                pièces en contact avec le produit et le cas échéant de les remplacer
                                pour maintenir l'intégrité hygiénique.

                                                                                                            62398-FR-230119

10                           EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31
6 Déclaration du fabricant

                                                 6     Déclaration du fabricant
                                                 6.1     3-A

                                                 Standard 74
                                                 Nous déclarons par la présente que les combinaisons d'appareils et
                                                 de raccords process des versions suivantes du VEGAPOINT 11, 21
                                                 satisfont aux exigences de la norme 3-A n° 74.

                                                 VEGAPOINT 11, 21 avec adaptateur hygiénique P
                                                 dans la version : P11(**).[A ou D][AC]*
                                                 dans la version : P21(**).****[A ou D][AC]***
                                                 •   En liaison avec les adaptateurs hygiéniques
                                                     –– HYGADAPT-P.D[AT, AR, U5, E2, E3, BA, AD, AC, KA, Q6, KW,
                                                        FR, FS ou 7F]

                                                 VEGAPOINT 11, 21 avec adaptateur hygiénique L
                                                 dans la version : P11(**).[A ou D][AF]*
                                                 dans la version : P21(**).****[A ou D][AF]***
                                                 •   En liaison avec les adaptateurs hygiéniques
                                                     –– HYGADAPT-L.D[AT, AR, E2, E3, BA, AD, AC, Q6, KW, FR, FS
                                                        ou 7F]

                                                 VEGAPOINT 21
                                                 Dans la version : P21(**).****[A ou D][AN, AP ou AQ]***

                                                 Standard 50
                                                 Nous déclarons par la présente que les combinaisons d'appareils
                                                 et de raccords process des versions suivantes du VEGAPOINT 31
                                                 satisfont aux exigences de la norme 3-A n° 50.
                                                 Le numéro de certificat associé pour le site VEGA Grieshaber KG,
                                                 Schiltach, Allemagne est 3808.

                                                 VEGAPOINT 31 avec adaptateur hygiénique P
                                                 dans la version : P31(**).****[A ou D][AC]*
                                                 •   En liaison avec les adaptateurs hygiéniques
                                                     –– HYGADAPT-P.D[AT, AR, U5, E2, E3, BA, AD, AC, KA, Q6, KW,
                                                        FR, FS ou 7F]

                                                 VEGAPOINT 31 avec adaptateur hygiénique L
                                                 Dans la version : P31(**).****[A ou D][AF]*
                                                 •   En liaison avec les adaptateurs hygiéniques
                                                     –– HYGADAPT-L.D[AT, AR, E2, E3, BA, AD, AC, Q6, KW, FR, FS
                                                        ou 7F]
62398-FR-230119

                                                 VEGAPOINT 31
                                                 Dans la version : P31(**).****[A ou D][AN, AP ou AQ]***

                  EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31                          11
6 Déclaration du fabricant

                               6.2     EHEDG
                               Nous déclarons par la présente que les combinaisons d'appareils et
                               de raccords process des versions suivantes du VEGAPOINT 11, 21,
                               31 satisfont aux exigences EHEDG doc. 2, doc. 8, doc. 10.

                               VEGAPOINT 11, 21, 31 avec adaptateur hygiénique P
                               Dans la version : P11(**).D[AC]*
                               Dans la version : P21(**).****D[AC]***
                               Dans la version : P31(**).****D[AC]***
                               •   En liaison avec les adaptateurs hygiéniques
                                   –– HYGADAPT-P.D[U5, E2, E3, BA, AD, AC, KA, Q6, KW, FR, FS
                                      ou 7F]
                                   –– HYGADAPT-P.D[AT ou AR] uniquement en combinaison avec
                                      Clamp seals Combifit International B.V., The Netherlands

                               VEGAPOINT 21, 31
                               Dans la version : P21(**).****D[AN, AP ou AQ]*** en combinaison
                               avec Clamp seals Combifit International B.V., The Netherlands
                               Dans la version : P31(**).****D[AN, AP ou AQ]*** en combinaison
                               avec Clamp seals Combifit International B.V., The Netherlands

                                                                                                            62398-FR-230119

12                           EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31
7 Certificat 3-A

                                                 7     Certificat 3-A
62398-FR-230119

                  EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31                13
7 Certificat 3-A

                                                                                                  62398-FR-230119

14                 EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31
7 Certificat 3-A
62398-FR-230119

                  EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31                15
7 Certificat 3-A

                                                                                                  62398-FR-230119

16                 EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31
7 Certificat 3-A
62398-FR-230119

                  EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31                17
8 Certificat EHEDG

                       8     Certificat EHEDG

                                                                                                    62398-FR-230119

18                   EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31
8 Certificat EHEDG
62398-FR-230119

                  EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31                  19
8 Certificat EHEDG

                                                                                                    62398-FR-230119

20                   EHEDG et 3-A, instructions de montage et de nettoyage • VEGAPOINT 11, 21, 31
Índice

Índice
1   Acerca de este documento...................................................................................................... 3
    1.1 Función............................................................................................................................. 3
    1.2 Alcance............................................................................................................................. 3
2   Normas 3-A-/EHEDG - significado e implementación........................................................... 4

3   Versiones de dispositivos........................................................................................................ 5

4   Montaje...................................................................................................................................... 6

5   Mantenimiento, limpieza y uso previsto................................................................................. 9

6   Declaración del fabricante..................................................................................................... 11
    6.1 3-A.................................................................................................................................. 11
    6.2 EHEDG........................................................................................................................... 12
7   Certificado 3-A........................................................................................................................ 13

8   Certificado EHEDG................................................................................................................. 18

                                                                                                                                                      62398-ES-230119

                                          Estado de redacción: 2023-01-19

2                                         EHEDG y 3-A, instrucciones de instalación y limpieza • VEGAPOINT 11, 21, 31
1 Acerca de este documento

                                                  1     Acerca de este documento
                                                  1.1    Función
                                                  Este manual le proporciona la información más importante para el
                                                  uso de interruptores de nivel.

                                                  VEGAPOINT 11, 21
                                                  según " EHEDG Doc. 2, Doc. 8, Doc. 10 y 3-A Sanitary Standard for
                                                  Sensors and Sensor Fittings and Connections, Number 74".

                                                  VEGAPOINT 31
                                                  según " EHEDG Doc. 2, Doc. 8, Doc. 10 y 3-A Sanitary Standard for
                                                  Level Sensing Devices for Dry Products, Number 50".

                                                  1.2    Alcance
                                                  La instrucción se aplica para interruptores límites VEGAPOINT 11,
                                                  21, 31 con conexiones a proceso y juntas higiénicas. Las conexiones
                                                  y las junta aparecen en la declaración del fabricante en el presente
                                                  documento.
62398-ES-230119

                  EHEDG y 3-A, instrucciones de instalación y limpieza • VEGAPOINT 11, 21, 31                           3
2 Normas 3-A-/EHEDG - significado e implementación

                             2     Normas 3-A-/EHEDG - significado e
                                   implementación
Significado de 3-A           3-A Sanitary Standards Incorporation (SSI) en los EE.UU. establece
                             normas para materiales, diseño y métodos de fabricación de com-
                             ponentes utilizados en procesos higiénicos. La organización también
                             supervisa el cumplimiento del diseño higiénico de estos componen-
                             tes. La conformidad es comprobada por un organismo independiente
                             CCE (Certified Conformance Evaluator). En caso de conformidad SSI
                             3-A emite una licencia de símbolo para el logotipo 3-A.

Significado de EHEDG         European Hygienic Engineering & Design Group (EHEDG) es un
                             consorcio de fabricantes de equipos y alimentos, proveedores de la
                             industria alimentaria, institutos de investigación y universidades. Su
                             objetivo principal es la promoción de alimentos seguros mediante la
                             mejora de la tecnología y el diseño higiénico en todos los campos
                             de producción de alimentos. Para ello la EHEDG ha elaborado, entre
                             otras cosas, directrices de diseño higiénico de las máquinas y equi-
                             pos, así como de la infraestructura de producción de alimentos.

Empleo de equipos se-        Para el uso en el sector alimentario según EHEDG o 3-A, se aplican
gún EHEDG y 3-A              requisitos especiales en comparación con las aplicaciones estándar.
                             Esto se aplica en particular a:
                             •   Versión de la carcasa (p. Ej. limpieza fácil)
                             •   Estructura de las conexiones a proceso (p. Ej. visibilidad posibles
                                 fugas)
                             •   Juntas (p.ej. según FDA y EG1935/2004, o resistentes al proceso
                                 y a los medios de limpieza)
                             •   Posición de montaje en el depósito (p. Ej. auto-drenaje)
                             •   Limpieza y mantenimiento (por ejemplo, intervalos, métodos)
                             Los logotipos EHEDG y 3-A demuestran que el diseño del dispositivo
                             ha sido comprobado y certificado. El certificado se refiere siempre a
                             una combinación de sensor y conexión de proceso.

                                                                                                           62398-ES-230119

4                            EHEDG y 3-A, instrucciones de instalación y limpieza • VEGAPOINT 11, 21, 31